Command ID: 106


Command property:


Asynchronous command.



Command action:


Reset all modules of the machine, erasing all documents created, rejecting the cards inside the transport and recover interlocks failure.


Syntax:


<command Name="ResetMachine" />



Reply:


<command Name="ResetMachine" valid="true" />



When the command is executed, the system reply with:



<command Name="ResetMachine" executed="true" >


and the transport module goes in Ready Status, the Interface goes in Ready Status and the Laser goes in Ready Status



If the command execution fails, the system reply with:



<command Name="reset" executed="false" error="[string]" >


The module or the modules generate(s) the error goes in Fault Status




Command purpose:


This command is used to reset the system in order to start a new card issuance.

Created with the Personal Edition of HelpNDoc: Write EPub books for the iPad