Command ID: 118


Command property:


Asynchronous command.


The Interface Status must be Ready to perform this operation.

If the status is different than Ready, the system reply with:


<command valid="false" error="Laser module not ready" />


Command action:


Load an existing SJF file inside the SamLight editor.

The laser pens inside the SJF file are NOT loaded, will be used the system standard laser pens.


WARNING: The entities inside the document must have an unique ID, including optional other layout already loaded.


Syntax:


<command name="LoadLayout" Module="[Integer]" Rotation="[Integer]" TemplateName="[String]" Template="[String]" />


Parameters:

Name

Mandatory

Description

Format

Standard value

Module

Yes

The module you want load the template

Integer

--------------------

TemplateName

Yes

The name of the layout, used for Mark Layout command

String

---------------------

Template

Yes

SJF file coded on Base64

String

---------------------

Rotation

No

Rotation of the layout, in degree

Integer

0




Reply:


<command name="LoadLayout" valid="true" />


During the command execution the Interface Status goes to Loading.



When the command is executed, the system reply with:



<command name="LoadLayout" Module="[Integer]" executed="true" >


If the document creation is done, the Interface Status goes to Ready.



If the command execution fails, the system reply with:


<command name="LoadLayout" Module="[Integer]" executed="false" >



If the document creation fails, the Interface Status goes to Error.




Command purpose:


This command is used to load an existing SJF file.