Set Laser Configuration
Command property:
Synchronous command.
NOTE: This changing can cause machine malfunctions and machine breaks! Please, use this command carefully.
Command action:
Set a new laser source configuration.
Syntax:
<command name="setlaserconfiguration" current="[Integer]" derivativegain="[Integer]" integrativegain="[Integer]" proportionalgain="[Integer]" setpoint="[Integer]" fan1="[Integer]" fan2="[Integer]" />
Parameters:
Name |
Mandatory |
Description |
Format |
current |
Yes |
Current level to the diode. |
Integer |
derivativegain |
Yes |
Derivative gain of PID temperature controller |
Integer |
integrativegain |
Yes |
Integrative gain of PID temperature controller |
Integer |
proportionalgain |
Yes |
Proportional gain of PID temperature controller |
Integer |
setpoint |
Yes |
Diode temperature setpoint |
Integer |
fan1 |
Yes |
Fan 2 and Fan 3 temperature lighting |
Integer |
fan2 |
Yes |
Fan 4 and Fan 5 temperature lighting |
Integer |
Reply:
<command valid="true" />
Command purpose:
This command is used to change factory laser configurations. These parameters are usually set in factory and must be changed only against diode or resonator changing.
Created with the Personal Edition of HelpNDoc: Easily create PDF Help documents