Command property:


Asynchronous command.


Command action:


Set the interface parameters, usually set in factory.


NOTE: This changing can cause machine malfunctions! Please, use this command carefully.

NOTE: in order to make this modification permanent, it is needed the Command and Reboot command at the end of the settings.


Syntax:


<command name="setinterfaceparameters" XGain="[Double]" YGain="[Double]" XOffset="[Double]" YOffset="[Double]" />


Parameters:

Name

Mandatory

Description

Format

XGain

Yes

X Gain related to Scan Head used.

Double

YGain

Yes

Y Gain related to Scan Head used.

Double

XOffset

Yes

X Offset related to physical position between the scan head and transport flipover.

Double

YOffset

Yes

Y Offset related to physical position between the scan head and transport flipover.

Double



Reply:


<command valid="true" />



When the command is executed, the system reply with:



<command name="SetInterfaceParameters" executed="true" />


If the command execution fails, the system reply with:



<command name="SetInterfaceParameters" executed="false" />




Command purpose:


This command is used to change the Interface parameters, used when a new scan head is installed or the scan head is moved respect the transport flipover.