Log File
Every module create different log entry.
The log file is created in the Log folder set in Configuration File
The log file have the name as YYYYMMDD.txt where:
- YYYY is the year
- MM is the month
- DD is the day
When the log file reach the size set in Configuration File the log file is compressed as YYYYMMDD-1.gz and a new file is created.
Every time the log file reach that size, a new compressed file is created with serial number: YYYYMMDD-2.qz YYYYMMDD-3.gz and so on.
NOTE: a high Log Level can generate big size log files faster! Use high log level only for test and debug!
At System Start some important informations are logged.
Here a sample of a standard boot up log file section:
11:24:00.281 - System: ------------------------------------System Start------------------------------------
11:24:00.296 - System: File version: 0.0.16.0 LogLevel: 0 Logdays: 30
11:24:00.390 - Vision: LIBRARY LOADING. FILE VERSION: 0.0.5.1 LOGLEVEL: 2
11:24:00.906 - Vision: CAMERA SELECTED: MATRIX VISION BLUE FOX
11:24:01.546 - MatrixCamDll: OPEN CAMERA START
11:24:04.875 - MatrixCamDll: DEVICE OPEN. PRODUCT TYPE: MVBLUEFOX-ML/IGC202BG DEVICE SERIAL: 30000192
11:24:04.968 - MatrixCamDll: EXPOSURE TIME: 20000 US GAIN: 0 DB
11:24:09.859 - MatrixCamDll: IMAGE TESTED. GREYTONE MEDIUM: 44.47
11:24:09.859 - MatrixCamDll: CAMERA CORRECTLY OPEN
11:24:09.875 - MatrixCamDll: IMAGE REQUEST SINGLE
11:24:13.515 - Vision: LIBRARY SELECTED: MATRIX VISION
11:24:13.515 - Vision: MATRIX LICENSES. XY: TRUE OCR: FALSE BARCODE: FALSE EDGE: FALSE
11:24:13.781 - Vision: INTERNAL LIBRARY CHECK. XY: TRUE OCR: FALSE BARCODE: FALSE EDGE: FALSE
11:24:13.828 - Scaps: LIBRARY LOADING. FILE VERSION: 0.0.10.8 LOGLEVEL: 2
11:24:14.031 - Scaps: SCAPS USC-1 DONGLE NUMBER: 15223
11:24:15.062 - Scaps: LASER PARAMETERS: X GAIN: 0.988 Y GAIN: 0.99 X OFFSET: 4.6 Y OFFSET: 3.2
11:24:15.062 - Scaps: TIME TO RETRIEVE: 1234.375 MS
11:24:15.078 - Scaps: LASER OVERRIDES: POWER: 80 SPEED: 100 FREQUENCY: 100
11:24:15.109 - EMTS: LIBRARY LOADING. FILE VERSION: 0.0.6.0 COMPORT SET: COM1 LOGLEVEL: 2
11:24:15.109 - EMTS: OPENING PORT
11:24:15.109 - EMTS: FW REQUEST
11:24:15.187 - EMTS: FIRMWARE VERSION: 0252ENC899 V24.05.01-FLIP 3D FW125.10.01 S/N 11120029
11:24:15.187 - EMTS: RESET FUNCTION REQUEST
11:24:20.031 - EMTS: ANSWER: 01510
11:24:20.109 - Laser: LIBRARY LOADING. FILE VERSION: 0.0.5.6 COMPORT SET: COM6 LOGLEVEL: 2
11:24:20.109 - Laser: OPENING PORT
11:24:20.109 - Laser: FW REQUEST
11:24:20.125 - Laser: FIRMWARE VERSION: 206
11:24:20.125 - Laser: KEEPALIVE ACTIVATED. INTERVAL: 15000 MS
11:24:21.109 - Laser: SETTINGS: 055500175000500002000030000700003000030000
11:24:21.125 - Laser: START STRING: 000 BINARY STRING: 000000000000
11:24:21.125 - Laser: OPENING LASER SHUTTER
11:24:21.140 - Laser: LASER SHUTTER REPLY: 0050800
11:24:21.546 - Laser: ANALOGS: 06560017200010000278000
11:24:21.609 - Display: LIBRARY LOADING. FILE VERSION: 0.0.3.2 COMPORT SET: COM5 LOGLEVEL: 0
11:24:22.812 - PCSC Wrapper: STARTING JAVA WRAPPER. LOG LEVEL: 2
11:24:23:078 - JAVA PCSC MODULE: Load JAVA Module
11:24:23:171 - JAVA PCSC MODULE: Check PCSC encoder
11:24:30:203 - JAVA PCSC MODULE: NO encoder connected. Java shut down
11:24:30.203 - PCSC Wrapper: WRAPPER STARTED. REPLY: ERROR
11:24:30.203 - PCSC Wrapper: JAVA MODULE NOT READY
11:24:30.203 - System: Error loading PcSc Wrapper: Java module not ready
The log structure is the same for every module:
HH:MM:SS:mmm - [MODULE]:
Where:
- HH is the hour
- MM is the minute
- SS is the second
- mmm is the millisecond
- MODULE is the module generate the log entry
Refers to the specific module section for low level commands understanding.
NOTE: every time you need support, please, send us the log files of the machine, possibly with high log level in the section the support is required.
Created with the Personal Edition of HelpNDoc: Single source CHM, PDF, DOC and HTML Help creation